DESCRIPTION
Contains the necessary parts and instructions required for upgrading any (six channel) make or model of heat treatment unit to provide the additional functionality, user benefits and cost savings provided by the ‘Advantage 3™’ linkable programmer/controller.
SPECIFICATIONS
Control
- Proportional Band: ± 5°C (10°F) / ± 10°C (20°F) / ± 20°C (40°F) / ± 40°C (80°F).
- Hold Back Setting: 10°C (20°F) / 20°C (40°F) / 40°C (80°F) / 60°C (120°F).
Power input
- Supply Voltage: 110/115 V a.c.
- Frequency: 50/60 Hz.
Signal output
- Type: Thermocouple Type K (NiCr/NiAl).
- Range: 0 to 1200°C (0 to 2200°F).
Accuracy
- Measurement: ± 0.3°C (0.6°F).
- Linearity: Better than ± 0.5°C (1°F) at any point.
- Calibration: ± 1 display digit (Uncertainty: 1 display digit).
Programmable values
- Start Temperature: °C or °F temperature uncontrolled up to.
- Rate of Rise: °C or °F per hour.
- Soak Temperature: °C or °F temperature to soak (hold) at.
- Soak Time: Time (hours:minutes) held at soak (hold).
- Rate of Fall: °C or °F per hour.
- Off Temperature: °C or °F temperature uncontrolled down from.
Environmental/safety
- Normal Operating Temperature range : -10 to 55°C.
- Storage Temperature: 10 to 90% Relative Humidity.
- Ambient Humidity: EMC: EN 61326:1998.
- CE Compliance: LVD: EN 61010-1:2001.
- Enclosure IP rating: Front: IP 64.
- Enclosure IP rating: Rear: IP 20.
- Panel Cut-out: 45mm +0.6 x 92mm +0.8.