DESCRIPTION
The heater is ideal for preheat of large welded constructions including steam drums, vessels and rotating equipment and are an alternative to our range of infrared Gas Surface Combustion Units (SCUs). Specifically designed to replace the costly and heavy induction equipment including SCU’s required to deliver preheats on vessels and large constructions, the infrared heater has an exceptionally fast heat up time and is lightweight in comparison to induction alternatives. Infra-red panels can be mounted on internal or external support rigs or on separate stands as single units. As single units the heater can be strategically positioned during the rotating operation necessary for welding circumferential seams of large heavy walled pressure vessels. The infrared heater is rugged, lightweight and comprises of a stainless steel container tray, a layer of silica fibre insulation and a shallow concave strip element manufactured in high temperature Kanthal.
Specifications
Current, A | Power, kW | Voltage, V | Dimensions, mm |
---|---|---|---|
180 | 5.4 | 30 | 530x240mm |
180 | 10.8 | 60 | 630x370mm |
180 | 10.8 | 60 | 995x235mm |
Transformer core
- Three phase, forced air cooled, class H, 50kVA
- Primary winding connected in Delta
- Secondary winding connected in Star
- Auxiliary winding: 110V a.c. 3.3kVA single phase
Primary supply
- Primary voltage: 380V, 415V, 440V
- Primary current: 76A, 70A, 66A
- Frequency: 50/60 Hz
Protection
- Three phase 80A circuit breaker with shunt trip
- Three primary core winding over temperature thermostats linked to circuit breaker shunt trip
Secondary outputs
- Output: 32.5V – 0V – 32.5V (for 30V and 60V heating element operation)
- Auxiliary outputs: Two 110V, 10A, 50/60Hz output sockets
- Number of temperature controlled output channels: 6 channels
- Maximum load per output channel: 8.1kW (e.g. three 60V, 2.7kW heating elements)
- Maximum current per output channel: 135A
Switching
- Six double pole, 180A, contractors with 110V a.c. coil
Temperature control
- Temperature measurement, display and control
- Degrees Fahrenheit or Degrees Centigrade
- Start temperature
- Temperature ramp up and down in degrees per hour
- Hold/soak temperature set point and hold/soak time period setting
Temperature recording
- Ambient temperature: Minus 0˚C to 50˚C
- Humidity: 20% to 80% RH, non-condensing is required (temperature x humidity < 3200)
- Environmental protection: IEC IPSO (front door of panel mounted unit)
- Input points: 12 Points
- Input thermocouple types: Thermocouple inputs- K,
- Reference range: Type K: -200˚C to 1370˚C (-326˚F to 249˚F)
- Printing system: Ink jet system, 6 colour
- Chart Width: 180mm
- Chart Length: Z fold 20m
- Chart Speed: 5 to 300mm per hour
Construction
- Case: 304 Stainless Steel case fitted with four 150mm nylon wheels
Dimensions
- Weight: 355kg
- Case Dimensions:
Height: 1545mm
Width: 680mm
Depth: 665mm